| NAME | C200 LOCATIONS *= status only | ABORT AND C201 ABORT GENERATOR LOCATION | TYPE OF LINK AND REPEATERS | TCLK Events: abort has occurred, abort system reset | NUMBER OF C200 ABORT CONCENTRATORS AND ABORT INPUT PANELS |
|---|---|---|---|---|---|
| MI Abort | MAC Room* MI60S MI60CR* MI60N MI62 MI8 MI10 MI20 MI30 MI40 MI50 MI52 | MI40 | Fiber link and Fiber Abort repeaters | $27, $24 | >=10 |
| TeV Abort | MCR A0 [A1..B4] C0 [C1..E4] F0 MI60CR* [F1..F4] | A0 | Copper link and RF Abort repeaters | $47,$48 | >=33 |
| Recycler Proton Dump | MAC Room* MI60S MI60CR* MI40 | MI40 | Fiber link and Fiber Abort repeaters | $F5, $E8 | >=2 |
| NAME | C200 LOCATIONS *= status only | C201 ABORT GENERATOR LOCATION | TYPE OF LINK AND REPEATERS | TCLK events: abort has occurred, abort system reset | NUMBER OF C200 ABORT CONCENTRATORS AND ABORT INPUT PANELS |
|---|---|---|---|---|---|
| P1 BP | MAC Room* F17 F0S MI52 MI60CR* | F17 | Fiber link and Fiber Abort repeaters | NA, 38+48+88 | >=3 |
| P2 BP | MAC Room* F2 F1 F0S MI60CR* | F2 | Fiber link and Fiber Abort repeaters | NA, 38+88 | >=3 |
| NUMI BP | MAC Room* MI60CR* MI60N MI60S MI62 MI65 NUMI Target Hall MSB MND AAT | MSB | Fiber link and Fiber Abort repeaters | A6, A8 | >=10 |
| miniBooNE BP | MAC Room* MI10 MI12 | MI12 | Fiber link and Fiber Abort repeaters | NA, B8 | >=2 |
| SWYD BP includes P3 | MAC Room* F2 F3 F4 TG-5 (SWYD) TG-5 (P3) MI60CR* outlying beamlines | P3 at F2 | Copper link in SWYD outlying beam areas. Fiber link and Fiber Abort Repeaters elsewhere. | NA, $38 | >=5 |
| PBAR BP Loop | MCR AP10 (3) AP30 (2) AP50 (2) AP0 (2) F23 MI60CR* F27 | MCR | Copper link | NA,$88 | >=12 |