Main Menu

PA0052 General Purpose Parameter Program


MNTN RANGE/Frame Grabbers (2)

Program: PA0052
<< Cryogenics stuff Topic pbar clock events/ P60/DTOA/6 >>
At F0 we have 3 sets of scopes, cameras, mountain range modules,
and frame grabbers for use.  A 4th MNTN Range module (Tev MNTN  
RNG 2) is currently disconnected.  The names and control are:   
                   UPDATED 7/2/90 by KGM                        
*MR MNTN RANGE 1|control params on M19sp25|drives scope/camera 0
                                                                
*MR MNTN RANGE 2|control params on M19sp26|drives scope/camera 2
(The OLD frame grabber controled by M56 looks ONLY at camera 2) 
*Tev MNTN RANGE 1|params on M19sp27|drives scope/camera 1       
                                                                
*Tev MNTN RANGE 2|params on M19sp28|currently disconnected      
                                                                
     "MR" or "Tev" refers to RF clock & marker source           

Level 3 Topics:
Frame Grabbr
Signals

Level 2 Topics:
Overview Cryogenics stuff
New Features MNTN RANGE/Frame Grabbers
*---->Collider Memo Pad<----* pbar clock events/ P60/DTOA/6
Commands Bunch Spreaders (MR)
SBD - Sampled Bunch Display Switchyard stuff
mults and bumps Tevatron Bunch Spreader
Display Options Pseudo-fixed target inj.
Plot Package Interfaces Transfers between machines
CATV channels ACL Commands
8 GeV Kickers MR RF OFF control
Mountain Ranges Bunch Length Monitors
Notes Expressions
Bob's list of dropped encl's Notify Channel modes
Schottkies, Roman pots, etc. Bugs
Collimators and lambertsons Suggestions


Page(s):
B(Booster) 2 , 3 , 5 , 6 , 7 , 8 , 9 , 11 , 12 , 18 , 19 , 27 , 28 , 43 , 56 , 69 , 71 , 99 , 109 , 111
C(Collider) 9 , 14 , 16 , 18 , 30 , 34 , 57 , 64 , 65 , 72 , 73 , 82 , 94
D(Diagnostic/Utility) 24 , 26 , 96 , 97 , 106
E(Experimental) 3 , 4 , 5 , 6 , 7 , 15 , 22 , 23 , 25 , 30 , 35 , 38 , 52 , 53 , 54 , 58 , 61 , 62 , 87 , 88 , 99 , 107 , 128 , 129
F(Refrigerator) 4 , 9 , 14 , 37 , 49 , 50 , 51 , 52 , 53 , 58 , 60 , 61 , 71 , 72 , 73 , 81
H(Hardware Diagnostic) 34 , 53 , 55
I(Main Injector) 4 , 5 , 8 , 10 , 18 , 19 , 21 , 26 , 27 , 34 , 58 , 59 , 63 , 64 , 65 , 66 , 81 , 133
L(Linac/Preacc) 2 , 3 , 4 , 5 , 6 , 7 , 8 , 12 , 14 , 19 , 20 , 26 , 30 , 38 , 41 , 44 , 46 , 48 , 49 , 66 , 68
M(Main Ring) 2 , 3 , 4 , 22 , 65 , 69
N(New Muon Lab) 9 , 10 , 11 , 25 , 26 , 31 , 49 , 50 , 51 , 52 , 53 , 67 , 68 , 118 , 119 , 120 , 121 , 122
P(P-Bar) 8 , 12 , 36 , 38 , 57 , 60 , 66 , 71 , 75 , 79 , 100 , 122 , 123 , 200 , 202
R(Recycler) 4 , 5 , 8 , 26 , 27 , 34 , 35 , 59 , 63 , 64 , 65 , 66 , 117 , 118 , 119 , 154 , 160 , 192
S(Switchyard) 3 , 4 , 15 , 16 , 17 , 18 , 21 , 41
T(Tevatron) 4 , 5 , 9 , 13 , 15 , 23 , 30 , 37 , 43 , 55 , 56 , 68 , 72 , 73 , 74 , 75 , 81 , 88 , 90 , 111 , 118 , 119 , 120
W(Work in Progress) 70 , 95 , 97 , 99 , 100

Callee(s): Data Pool Manager Peek SA (SA0020) , TO PLOT TOROID CURRENT ON STORAGE SCOPE (SA0021) , Electron Cooling losses plot (SA1022) , Linac Toroid and Losses Plot (SA1046) , This is an interpretive graphical display (Lex SA). (SA1082) , Switchyard SWIC Display (SA1086)